<?xml version="1.0" encoding="UTF-8"?><mets:mets xmlns:mads="http://www.loc.gov/mads/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:tef="http://www.abes.fr/abes/documents/tef" xmlns:metsRights="http://cosimo.stanford.edu/sdr/metsrights/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mets="http://www.loc.gov/METS/">
    <mets:metsHdr ID="rennes1-ori-wf-1-17240" CREATEDATE="2022-10-11T22:28:00" LASTMODDATE="2022-10-11T22:28:01">
  <mets:agent ROLE="CREATOR">
            <mets:name>Université de Rennes 1</mets:name>
        </mets:agent>
</mets:metsHdr>
    <mets:dmdSec ID="desc_expr" CREATED="2022-10-11T22:28:00">
  <mets:mdWrap MDTYPE="OTHER" OTHERMDTYPE="tef_desc_these">
            <mets:xmlData>
                <tef:thesisRecord>
     <dc:title xml:lang="fr">Reproductibilité de l’oxymétrie transcutanée d’effort chez des patients avec une artériopathie des membres inférieurs</dc:title>
     <dcterms:alternative xml:lang="en">Reproducibility of transcutaneous oxygen pressure measurements in patients with lower extremity 
artery disease</dcterms:alternative>
     <dc:subject xml:lang="fr">AOMI</dc:subject><dc:subject xml:lang="fr">claudication</dc:subject><dc:subject xml:lang="fr">fiabilité</dc:subject><dc:subject xml:lang="fr">oxymétrie deffort</dc:subject>
     <dc:subject xml:lang="en">lower extremity artery disease</dc:subject><dc:subject xml:lang="en">reliabilit</dc:subject><dc:subject xml:lang="en">transcutaneous oxygen pressure</dc:subject>
     <tef:sujetRameau><tef:vedetteRameauNomCommun>
						<tef:elementdEntree autoriteSource="Sudoc" autoriteExterne="031735614">Oxymétrie</tef:elementdEntree>
					</tef:vedetteRameauNomCommun><tef:vedetteRameauNomCommun>
						<tef:elementdEntree autoriteSource="Sudoc" autoriteExterne="027557219">Obstruction des artères</tef:elementdEntree>
      <tef:subdivision autoriteSource="Sudoc" type="subdivisionDeSujet" autoriteExterne="027803805">Diagnostic</tef:subdivision>
					</tef:vedetteRameauNomCommun><tef:vedetteRameauNomCommun>
						<tef:elementdEntree autoriteSource="Sudoc" autoriteExterne="027364437">Membre inférieur</tef:elementdEntree>
					</tef:vedetteRameauNomCommun><tef:vedetteRameauNomCommun>
						<tef:elementdEntree autoriteSource="Sudoc" autoriteExterne="027865061">Ischémie‎</tef:elementdEntree>
					</tef:vedetteRameauNomCommun><tef:vedetteRameauNomCommun>
						<tef:elementdEntree autoriteSource="Sudoc" autoriteExterne="164393749">Claudication</tef:elementdEntree>
					</tef:vedetteRameauNomCommun><tef:vedetteRameauNomCommun>
						<tef:elementdEntree autoriteSource="Sudoc" autoriteExterne="219950997">Reproductibilité (sciences) </tef:elementdEntree>
					</tef:vedetteRameauNomCommun></tef:sujetRameau>
     
     
     
     
     
     <dcterms:abstract xml:lang="fr">Objectif:  L’oxymétrie transcutanée d’effort (TcPo2 d’effort) peut être utilisée pour le diagnostic d’Artériopathie Oblitérante des Membres Inférieurs (AOMI) et permet l’estimation de l’ischémie de membre pendant l’effort. Sa fiabilité test-retest chez des patients AOMI avec distance maximale de marche (DMM) ≤ 300m n’est pas connue. L’objectif de cette étude est d’évaluer la fiabilité test-restest, l’erreur standard de mesure et le changement minimal detectable des valeurs de DROP d’oxymétrie d’effort chez des patients artéritiques claudicants. Méthodes: Les données ont été collectées prospectivement chez l’ensemble des 23 patients inclus dans l’étude randomisée contrôlée ELECTROPAD ayant effectué deux tests d’oxymétrie d’effort dans un intervalle d’un mois. Le delta de pression en oxygène calculé à partir de valeur de repos (DROP) a été mesuré aux 2 fesses (proximal) et 2 mollets (distal). La reproductibilité test-retest a été évaluée en mesurant les valeurs d’oxymétrie deux fois dans un intervalle d’un mois. La reproductibilité test-retest a été exprimée comme erreur standard de mesure et le coefficient de correlation intraclasse (ICC). Pour l’analyse qualitative (AOMI/ pas d’AOMI), l’analyse de l’agrément entre les deux mesures a été exprimé en tant qu’accord spécifique positif et accord spécifique négatif. Resultats: Vingt-trois patients artéritiques (62+/-9 ans) ont été inclus. Les erreurs standards de mesure du DROP au niveau proximal et distal étaient de 7,5 mmHg et 8,6 mmHg respectivement. L’erreur standard de mesure de toutes les valeurs (proximales et distales) était de 8 mmHg et le changement minimal détectable était de 35 mmHg. Les ICCs étaient de 0,63 [0,45, 0.79] et 0,67 [0,50, 0,81] au niveau proximal et distal respectivement. Conclusion: L’oxymétrie transcutanée d’effort avec mesure du DROP a une fiabilité test-retest mo-dérée chez les patients artéritiques avec DMM ≤ 300m..Pour un individu donné, une amélioration ou une détérioration du DROP ≥35 mmHg après une intervention sera nécessaire pour être confiant à 95% qu’un changement est significatif. Elle devrait être considérée dans l’évaluation de l’impact d’une thérapeutique chez des patients claudicants artériels.</dcterms:abstract>
     <dcterms:abstract xml:lang="en">Objective: Exercise transcutaneous oxygen pressure treadmill test (Exercise-TcPO2) can be used to diagnose Lower Extremity Artery Disease (LEAD) and allows the quantification of limb ischemia during exercise. The exercise-tcPO2’s test-retest reliability in patients with LEAD and maximum walking distance&lt;300m is unknown. The aim of this study was to evaluate the test-retest reliability, typical error of measurement (TEM) and Minimal Detectable Change (MDC) of exercise tcPO2 in patients with arterial claudication. Methods: Data was collected prospectively from all 23 patients that performed two treadmill tests within a 1-month interval included in the ELECTROPAD Randomized Controlled Trial study. Delta from Rest of Oxygen Pressure (DROP) values were measured at both buttocks (proximal) and both calves (distal). Test-retest repro-ducibility was assessed by recording transcutaneous oximetry measurements twice within a 1-month interval. Test-retest reproducibility was expressed as standard error of measurement (SEM) and intra-class correlation coefficients (ICC). For the qualitative analysis (LEAD/no LEAD), analysis of agreement between the two was expressed for the positive and the negative ratings. Results: Twenty-three LEAD patients (62+/-9 years old) were included. The standard errors of measurement of DROP at the proximal and distal levels were 7.5 mmHg and 8.6 mmHg, respectively. The SEM for all (proximal and distal) DROP values was 8 mmHg and the minimal detectable change in DROP was 35mmHg. ICC were 0.63 [0.45, 0.79] and 0.67 [0.50, 0.81] for the proximal and distal levels. Conclusion: Exercise-TcPO2 with measurement of DROP values has a moderate test-retest reliability in clau-dicant LEAD patients with MWD≤ 300m. For an individual, an improvement or deterioration in DROP of ≥35mmHg after an intervention would be required to be 95% confident that the change is significant. It should be considered in evaluating the impact of treatment in patients with claudication.</dcterms:abstract>
     <dc:type>Electronic Thesis or Dissertation</dc:type><dc:type xsi:type="dcterms:DCMIType">Text</dc:type>
     <dc:language xsi:type="dcterms:RFC3066">en</dc:language>
    </tef:thesisRecord>
            </mets:xmlData>
        </mets:mdWrap>
</mets:dmdSec>
    <mets:dmdSec ID="desc_edition" CREATED="2022-10-11T22:28:00">
  <mets:mdWrap MDTYPE="OTHER" OTHERMDTYPE="tef_desc_edition">
            <mets:xmlData>
                <tef:edition><dcterms:medium xsi:type="dcterms:IMT">application/pdf</dcterms:medium><dcterms:extent>1 : 447 Ko</dcterms:extent><dc:identifier xsi:type="dcterms:URI">https://ged.univ-rennes1.fr/nuxeo/site/esupversions/d834b7c6-0cd2-4cbd-9081-edf4e138226e</dc:identifier></tef:edition>
            </mets:xmlData>
        </mets:mdWrap>
</mets:dmdSec>
    <mets:amdSec>
        <mets:techMD ID="admin_expr" CREATED="">
            <mets:mdWrap MDTYPE="OTHER" OTHERMDTYPE="tef_admin_these">
                <mets:xmlData>
                    <tef:thesisAdmin>
                        <tef:auteur>
       <tef:nom>Tueguem Moyo</tef:nom>
       <tef:prenom>Thérèse</tef:prenom>
       
       <tef:dateNaissance>1992-10-02</tef:dateNaissance>
       <tef:nationalite scheme="ISO-3166-1">XX</tef:nationalite>
       <tef:autoriteExterne autoriteSource="Sudoc">269870180</tef:autoriteExterne>
       <tef:autoriteExterne autoriteSource="mailPerso">paolamt2000@yahoo.fr</tef:autoriteExterne>
      </tef:auteur>
                        <dc:identifier xsi:type="tef:NNT">2022REN1M230</dc:identifier>
                        <dc:identifier xsi:type="tef:nationalThesisPID">http://www.theses.fr/2022REN1M230</dc:identifier>
                        <dcterms:dateAccepted xsi:type="dcterms:W3CDTF">2022-10-26</dcterms:dateAccepted>
                        <tef:thesis.degree>
                            <tef:thesis.degree.discipline xml:lang="fr">Médecine vasculaire</tef:thesis.degree.discipline>
                            <tef:thesis.degree.grantor>
        <tef:nom>Universite de Rennes 1</tef:nom><tef:autoriteInterne>thesis.degree.grantor_1</tef:autoriteInterne>
        
        <tef:autoriteExterne autoriteSource="Sudoc">02778715X</tef:autoriteExterne>
       </tef:thesis.degree.grantor>
                            <tef:thesis.degree.level>Doctorat (thèse d'exercice)</tef:thesis.degree.level>
                        </tef:thesis.degree>
                        <tef:theseSurTravaux>non</tef:theseSurTravaux>
                        <tef:avisJury>oui</tef:avisJury><tef:directeurThese><tef:nom>Mahé</tef:nom><tef:prenom>Guillaume</tef:prenom><tef:autoriteInterne>intervenant_1</tef:autoriteInterne><tef:autoriteExterne autoriteSource="Sudoc">159723434</tef:autoriteExterne></tef:directeurThese>
      
      
      
                        
                        <tef:oaiSetSpec>ddc:610</tef:oaiSetSpec>
                        
                    <tef:MADSAuthority authorityID="intervenant_1" type="personal"><tef:personMADS><mads:namePart type="family">Mahé</mads:namePart><mads:namePart type="given">Guillaume</mads:namePart></tef:personMADS></tef:MADSAuthority><tef:MADSAuthority authorityID="thesis.degree.grantor_1" type="corporate"><tef:personMADS><mads:namePart>Universite de Rennes 1</mads:namePart><mads:description>Sciences et technologie, medecine, pharmacie, odontologie, droit, economie, gestion, philosophie</mads:description></tef:personMADS></tef:MADSAuthority></tef:thesisAdmin>
                </mets:xmlData>
            </mets:mdWrap>
        </mets:techMD><mets:techMD ID="file_1"><mets:mdWrap MDTYPE="OTHER" OTHERMDTYPE="tef_tech_fichier"><mets:xmlData><tef:meta_fichier>
     <tef:encodage>ASCII</tef:encodage>
     <tef:formatFichier>PDF</tef:formatFichier>
     
     
     
     <tef:taille>457746</tef:taille>
    </tef:meta_fichier></mets:xmlData></mets:mdWrap></mets:techMD>
        
        <mets:rightsMD ID="dr_expr_thesard" CREATED="">
            <mets:mdWrap MDTYPE="OTHER" OTHERMDTYPE="tef_droits_auteur_these">
                <mets:xmlData>
                    <metsRights:RightsDeclarationMD>
                        <metsRights:Context CONTEXTCLASS="GENERAL PUBLIC">
                            <metsRights:Permissions DISCOVER="true" DISPLAY="false" COPY="true" DUPLICATE="true" MODIFY="false" DELETE="false" PRINT="true"/>
       <metsRights:Constraints CONSTRAINTTYPE="TIME" OTHERCONSTRAINTTYPE="">
								
        <metsRights:ConstraintDescription>restriction 2022-10-26 2022-11-26</metsRights:ConstraintDescription>
							</metsRights:Constraints>
                        </metsRights:Context>
                    </metsRights:RightsDeclarationMD>
                </mets:xmlData>
            </mets:mdWrap>
        </mets:rightsMD>
        <mets:rightsMD ID="dr_expr_univ" CREATED="">
            <mets:mdWrap MDTYPE="OTHER" OTHERMDTYPE="tef_droits_etablissement_these">
                <mets:xmlData>
                    <metsRights:RightsDeclarationMD>
                        <metsRights:Context CONTEXTCLASS="GENERAL PUBLIC">
                            <metsRights:Permissions DISCOVER="false" DISPLAY="false" COPY="false" DUPLICATE="false" MODIFY="false" DELETE="false" PRINT="false"/>
       <metsRights:Constraints CONSTRAINTTYPE="TIME" OTHERCONSTRAINTTYPE="">
								
        
        <metsRights:ConstraintDescription>confidentialité 2022-10-26 2023-06-30</metsRights:ConstraintDescription>
							</metsRights:Constraints>
                        </metsRights:Context>
                    </metsRights:RightsDeclarationMD>
                </mets:xmlData>
            </mets:mdWrap>
        </mets:rightsMD>
        <mets:rightsMD ID="dr_version" CREATED="">
            <mets:mdWrap MDTYPE="OTHER" OTHERMDTYPE="tef_droits_version">
                <mets:xmlData>
                    <metsRights:RightsDeclarationMD>
                        <metsRights:Context CONTEXTCLASS="GENERAL PUBLIC">
                            <metsRights:Permissions DISCOVER="false" DISPLAY="false" COPY="false" DUPLICATE="false" MODIFY="false" DELETE="false" PRINT="false"/>
       <metsRights:Constraints CONSTRAINTTYPE="TIME" OTHERCONSTRAINTTYPE="">
								
        <metsRights:ConstraintDescription>restriction 2022-10-26 2023-06-30</metsRights:ConstraintDescription>
							</metsRights:Constraints>
                        </metsRights:Context>
                    </metsRights:RightsDeclarationMD>
                </mets:xmlData>
            </mets:mdWrap>
        </mets:rightsMD>
    </mets:amdSec>
    <mets:fileSec>
  <mets:fileGrp ID="FGrID1" USE="archive"><mets:file ID="FID1" ADMID="file_1" MIMETYPE="application/pdf" USE="maitre"><mets:FLocat LOCTYPE="URL" xlink:href="https://ged.univ-rennes1.fr/nuxeo/site/esupversions/d834b7c6-0cd2-4cbd-9081-edf4e138226e"/></mets:file></mets:fileGrp>
 </mets:fileSec>
    <mets:structMap TYPE="logical">
        <mets:div DMDID="desc_expr" ADMID="dr_expr_thesard dr_expr_univ admin_expr" TYPE="THESE" CONTENTIDS="http://ori-oai-search.univ-rennes1.fr/uid/rennes1-ori-wf-1-17240/oeuvre">
            <mets:div ADMID="dr_version" TYPE="VERSION_COMPLETE" CONTENTIDS="http://ori-oai-search.univ-rennes1.fr/uid/rennes1-ori-wf-1-17240/oeuvre/version">
                <mets:div DMDID="desc_edition" TYPE="EDITION" CONTENTIDS="http://ori-oai-search.univ-rennes1.fr/uid/rennes1-ori-wf-1-17240/oeuvre/version/edition">
                    <mets:fptr FILEID="FGrID1"/>
                </mets:div>
            </mets:div>
        </mets:div>
    </mets:structMap>
</mets:mets>